Cable

Found: 35
Cables for security systems and low-voltage networks are the foundation of any engineering infrastructure. Without a properly chosen cable, neither a surveillance camera, nor a fire detector, nor an access control system will work stably. The SAT Solutions catalog offers cables of various types and cross-sections: signal, twisted pair, fire-resistant, electrical — everything needed for installing low-voltage and power lines at sites of any scale in Tashkent and throughout Uzbekistan. How to choose & FAQ ↓
Sort
FTP-KANIHAD cable Cat 5 (indoor, black) 4*2*0.5 305 m
FTP Cat5 4×2×0,5
FTP-KANIHAD cable Cat 5 (indoor, black) 4*2*0.5 305 m
In stock
from 469 900 UZS
KKV-KANIHAD cable 2*0.35 300 m
KKV 2×0,35
KKV-KANIHAD cable 2*0.35 300 m
In stock
from 741 900 UZS
UTP-KANIHAD cable Cat 5 (indoor, orange) 4*2*0.5 305 m
UTP Cat5 4×2×0,5
UTP-KANIHAD cable Cat 5 (indoor, orange) 4*2*0.5 305 m
In stock
from 432 900 UZS
UTP-KANIHAD cable Cat 6 (outdoor, black) 4*2*0.56 305 m
UTP Cat6 4×2×0,56
UTP-KANIHAD cable Cat 6 (outdoor, black) 4*2*0.56 305 m
In stock
from 469 900 UZS
KPSng(A)-FRLS Cable 1x2x0.5
KPSng(A)-FRLS Cable 1x2x0.5
In stock
from 1 026 900 UZS
KPSng(A)-FRLS Cable 1x2x0.75
KPSng(A)-FRLS Cable 1x2x0.75
In stock
from 1 484 900 UZS
KSVPP-6 Cable 4*2*0.57
KSVPP-6 Cable 4*2*0.57
In stock
from 8 290 UZS
KSVPPE-6 Cable 4*2*0.57
KSVPPE-6 Cable 4*2*0.57
In stock
from 9 490 UZS
PUGNP Cable 2*2.5
PUGNP Cable 2*2.5
In stock
from 14 090 UZS
PUGNP KANIHAD Cable 2*0.35 (black, 1000 m)
KSVPV Twisted-Pair Cable 4*2*0.52 gray UTP
KSVPV-6A Twisted-Pair Cable 4*2*0.57
NewPower Cord C13 to Schuko, 1.5 m
C13 1.5m
Power Cord C13 to Schuko, 1.5 m
In stock
from 37 090 UZS
Field Cable P 274 M 2*0.5 (field)
Field Cable P 274 M 2*0.5 (field)
In stock
from 2 690 UZS
Communication Cable KSVVEng 4x0.8
Communication Cable KSVVEng 4x0.8
In stock
from 7 590 UZS
Communication Cable KSVVeng 2x0.8
Communication Cable KSVVeng 2x0.8
In stock
from 4 390 UZS
Signal Cable KSVPVE-6 4*2*0.57
Signal Cable KSVPVE-6 4*2*0.57
In stock
from 9 890 UZS
Signal Cable KSVPPETross 4*2*0.52
Signal Cable KSVPPETross 4*2*0.52
In stock
from 7 590 UZS
Signal Cable KSPV 2*0.4
Signal Cable KSPV 2*0.4
In stock
from 1 110 UZS
Signal Cable KSPV 2*0.5
Signal Cable KSPV 2*0.5
In stock
from 1 390 UZS
Signal Cable KSPV 4*0.4
Signal Cable KSPV 4*0.4
In stock
from 1 790 UZS
Signal Cable PUGNP 2*0.5
Signal Cable PUGNP 2*0.5
In stock
from 3 490 UZS
Electrical Cable PVS 3*2.5
Electrical Cable PVS 3*2.5
In stock
from 22 190 UZS
Electrical Cable PUGNP 2*0.75
Electrical Cable PUGNP 2*0.75
In stock
from 4 890 UZS
PUGNP 3*2,5 electrical cable
PUGNP 3*2,5 electrical cable
In stock
from 20 690 UZS
TRP 2*0,4 electrical cable
TRP 2*0,4 electrical cable
In stock
from 1 190 UZS
TRP 2*0,5 electrical cable
TRP 2*0,5 electrical cable
In stock
from 1 690 UZS
KANIHAD GNT-10703-60 optical HDMI cable
GNT-10703-60
KANIHAD GNT-10703-60 optical HDMI cable
In stock
from 617 900 UZS
FIBER OPTIC 2CORE optical drop cable
Drop 2-core
FIBER OPTIC 2CORE optical drop cable
In stock
from 617 900 UZS
PVS 2*0,75 electrical wire
PVS 2*0,75 electrical wire
In stock
from 5 490 UZS
PUGNP 2*1,5 electrical wire
PUGNP 2*1,5 electrical wire
In stock
from 8 090 UZS

Cable — guide & FAQ

Cables for security systems and low-voltage networks are the foundation of any engineering infrastructure. Without a properly chosen cable, neither a surveillance camera, nor a fire detector, nor an access control system will work stably. The SAT Solutions catalog offers cables of various types and cross-sections: signal, twisted pair, fire-resistant, electrical — everything needed for installing low-voltage and power lines at sites of any scale in Tashkent and throughout Uzbekistan.

The choice of cable is determined by the type of system, the route length, the installation conditions, and fire safety requirements. For security alarm systems, signal cables of the KSPV and KSVPPETross types are suitable, for structured cabling networks — category 5e twisted pair, for equipment power — PVS and PUGNP wires of the required cross-section. Fire-resistant cables of the FRLS and ng(A) grades are mandatory on evacuation routes and in places where the cable line must remain functional during a fire. Our catalog with a constant range in stock allows you to buy cable of the required type and cross-section in Tashkent with delivery to the site.

Professional installation of low-voltage systems is impossible without an accurate calculation of the cable route. Experienced SAT Solutions engineers select the type and grade of cable based on the design solution, environmental conditions, and regulatory requirements. This approach eliminates rework and guarantees the durability of the system throughout its entire service life.

How to choose

  • System type: for security and fire alarms, signal cables are used (KSPV, KSVVEng, KPSng-FRLS), for surveillance — coaxial cable or twisted pair, for local networks — category 5e twisted pair and higher, for power supply — PVS or PUGNP power wires.
  • Conductor cross-section: determines the permissible current and voltage drop on long routes. For signal circuits, 0.4–0.8 mm is usually sufficient, for 12/24 V power — from 0.75 mm², for 220 V power lines — from 1.5 to 2.5 mm² and more.
  • Number of conductors: depends on the connection scheme. Two-conductor cables are used for simple loops, four-conductor and multi-conductor ones — for RS-485 interfaces, addressable systems, and combined routing of power and signal.
  • Shielding: shielded cables (FTP, E in the marking) protect against electromagnetic interference — important at industrial sites and near power lines.
  • Fire safety class: on evacuation routes and in zones with heightened fire safety requirements, cables with the ng(A), FRLS indices, or a combination of them are needed — they do not spread flame and emit minimal smoke.
  • Installation conditions: for outdoor installation and in soil, cables with a support wire or armor are needed (KSVPPETross), for indoor use — standard designs.
  • Route length: on long lines, voltage drop is critical — a correct cross-section calculation avoids power failures of remote devices.

Applications

  • Residential and commercial sites: apartments, office centers, shopping complexes — installation of security alarms, intercoms, video surveillance, and local networks.
  • Industrial enterprises and warehouses: access control systems, fire automation, IP video surveillance along the perimeter and inside production zones.
  • Educational and healthcare facilities: schools, universities, hospitals — where the fire-safety requirements for cable lines are especially strict.
  • Hotels: cabling infrastructure for security, telephony, IPTV, and room-based access management systems.
  • Government and restricted-access sites: administrative buildings, banks, checkpoints — with heightened requirements for the reliability and fire resistance of cable routes.
  • Outdoor installations and perimeter: video surveillance in open areas, fences, parking lots — using support-wire cables.

Brands and models in the catalog

  • The range includes cables of domestic and Russian manufacture under the general "Other equipment" group — proven grades compliant with O‘z DSt and used in real projects throughout Uzbekistan.
  • Signal cables KSPV 2x0.4 and KSVPPETross 4x2x0.52 — for installing security alarms, motion sensors, and perimeter protection with support-wire routing in open areas.
  • Communication cables KSVVEng 4x0.8 and twisted pair KSVPPE 4x2x0.52 in FTP and UTP designs — for structured cabling networks, IP video surveillance, and data transmission inside buildings.
  • Fire-resistant cable KPSng(A)-FRLS 1x2x0.5 — for addressable fire systems and loops laid along evacuation routes in accordance with fire code requirements.
  • Electrical wires PVS 2x0.75, PVS 3x2.5, and PUGNP 2x2.5 — for connecting power to equipment, socket groups, and distribution boxes at sites.

Frequently asked questions

How does FTP cable differ from UTP?
FTP is twisted pair with a common foil shield protecting against external electromagnetic interference. UTP is unshielded twisted pair, used where interference is minimal. For industrial sites and zones with power equipment, FTP is recommended.
What cable is needed for fire alarms?
For fire alarms on evacuation routes, cables with the ng(A)-FRLS index are used — they do not spread flame in a bundle and emit a limited amount of smoke. This requirement is explicitly stated in fire safety codes.
Can twisted pair be used for analog video surveillance?
Yes, with the use of passive or active transceivers (baluns), twisted pair is used to transmit an analog video signal over distances of up to 300–500 m. For IP video surveillance, category 5e twisted pair is the standard.
How do I calculate what cable cross-section is needed to power cameras?
The cross-section is chosen based on the total load current and the route length, so that the voltage drop does not exceed the permissible level. Our engineers perform the calculation free of charge when preparing a project or quote.
Do you deliver cable to the regions of Uzbekistan?
Yes, SAT Solutions arranges delivery to sites anywhere in Uzbekistan. Delivery terms and conditions are agreed upon when placing the order.
🛠Turnkey serviceStructured Cabling & LAN Installation in Tashkent, Uzbekistan — design and installation→