Addressable voice fire sounder QR Systems OR-101
Addressable voice fire sounder QR Systems OR-101 — фото 2
Addressable voice fire sounder QR Systems OR-101 — фото 3
● QR Systems In stockNew

Addressable voice fire sounder QR Systems OR-101

Addressable voice sounder on the wired loop: pre-recorded message, 1 W, 80 dB at 1 m, 200–5000 Hz, DC 24 V supply, 1 address slot, IP30.

504 900 UZS
▸
Type
voice fire sounder, addressable
▸
Interface
wired loop (PLS)
▸
Address slots
1
⚡
Power supply
DC 24 V ±20 % (12 V ±20 %)

Specifications

Type
voice fire sounder, addressable
Interface
wired loop (PLS)
Address slots
1
Power supply
DC 24 V ±20 % (12 V ±20 %)
Current consumption
≤ 10 mA standby, ≤ 72 mA Fire
Power / sound pressure
at least 1 W / at least 80 dB at 1 m
Frequency range
200–5000 Hz
Operating temperature
−25…+55 °C, humidity up to 93 % at 40 °C
Housing
IP30, 109×109×57 mm, 0.37 kg
Average service life
10 years

Description

The QR Systems OR-101 voice fire sounder is designed to alert people in case of fire with a pre-recorded voice message and to give fire and emergency audible signals. The sounder operates under control of a fire control panel within a QR Systems automatic fire alarm system, connects to the wired communication loop (PLS) and occupies one address slot. Messages are stored in non-volatile memory; rated power is at least 1 W, sound pressure at least 80 dB at 1 m, frequency range 200–5000 Hz. Testing is done with the Test button on the housing or from the controller menu, and an LED indicator shows the status. The sounder is installed indoors and is used by designers and installation companies to build a type 3 voice evacuation system without additional equipment.

Advantages

  • Type 3 voice evacuation system without additional equipment — voice notification is built on the sounders themselves in the addressable loop
  • Non-volatile memory — the recorded message is retained when power is lost
  • Audible and voice notification in one device — alarm tone and spoken instruction
  • At least 1 W and 80 dB at 1 m, 200–5000 Hz range — intelligible speech in the room
  • Own address in the system and test by button or from the controller menu — each sounder is checked without removal
  • Current no more than 10 mA in standby and 72 mA in Fire mode, IP30, −25…+55 °C, service life 10 years

Applications

  • Type 3 voice evacuation systems based on the QR Systems addressable system
  • Office and administrative buildings with voice fire notification
  • Shopping centres, hotels and educational institutions
  • Industrial and warehouse premises protected from precipitation
  • Sites that need both an alarm tone and a spoken evacuation instruction

Frequently asked questions

Is a separate amplifier or voice evacuation unit required?
According to the manufacturer, a site is equipped with a type 3 voice evacuation system without additional equipment: the sounder stores the pre-recorded message in non-volatile memory and plays it on command from the fire control panel.
How is the sounder powered and how many addresses does it occupy?
Supply DC 24 V ±20 % (the data sheet also lists 12 V ±20 %), current no more than 10 mA in standby and no more than 72 mA in Fire mode. Communication with the panel is over the wired loop; the sounder occupies one address slot.
How is the sounder tested after installation?
With the Test button on the sounder or from the controller menu. The status is shown by the LED indicator. The sounder is rated for continuous round-the-clock operation and is a repairable, periodically serviced product.
🛠Turnkey servicePublic Address and Voice Evacuation in Tashkent — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.