Addressable expansion module QR Systems AMR-4
● QR Systems In stockNew

Addressable expansion module QR Systems AMR-4

Addressable module with 4 loops of conventional detectors (up to 32 each), 4 supervised outputs up to 0.45 A and a 250 V / 2 A dry-contact relay; PLS interface.

660 900 UZS
▸
Interface
PLS
▸
Address slots
10
▸
Loops
4, up to 32 detectors per loop (standby current ≤ 45 µA)
▸
Outputs
4 supervised for open and short circuit, 24 V ± 20 %, up to 0.45 A

Specifications

Interface
PLS
Address slots
10
Loops
4, up to 32 detectors per loop (standby current ≤ 45 µA)
Outputs
4 supervised for open and short circuit, 24 V ± 20 %, up to 0.45 A
Relay
1 dry contact, up to 250 V / 2 A
Power supply
DC 24 V ± 20 % (main/standby)
Current consumption
no more than 50 mA excluding outputs
Operating temperature
−10…+55 °C
Housing
IP20, 145×90×41 mm, max 200 g
Average service life
10 years

Description

The QR Systems AMR-4 addressable expansion module connects conventional fire detectors to a QR Systems addressable analogue system, controls notification and building systems, and reports the state of every loop and output to the control panel. Four alarm loops connect to the module, each with up to 32 conventional detectors (smoke, heat, manual) whose standby current is no more than 45 µA. Four freely programmable 24 V outputs supervised for open and short circuit drive sounders and light indicator panels, while a dry-contact relay up to 250 V / 2 A starts fire suppression or smoke control or shuts down ventilation. The module operates over the PLS wired addressable line with the addressable analogue fire alarm control panel and with the KS-02-250 system controller, occupying 10 address slots. The board carries LED indicators, Test and Reset buttons and a tamper switch.

Advantages

  • 4 loops with up to 32 detectors each — conventional detectors work in a QR Systems addressable analogue system
  • 4 outputs 24 V ± 20 % up to 0.45 A supervised for open and short circuit — sounders and panels with line integrity monitoring
  • 250 V / 2 A dry-contact relay — starting fire suppression or smoke control, or shutting down ventilation
  • Detailed information on each loop and output at the panel — a fault is located down to the specific line
  • DC 24 V ± 20 % supply from main and standby sources, no more than 50 mA excluding outputs
  • Test and Reset buttons, LED indication and tamper switch — checks and servicing on site

Applications

  • Migrating conventional loops to a QR Systems addressable analogue system
  • Notification control: sounders and light indicator panels in the loop area
  • Starting fire suppression and smoke control, shutting down ventilation on panel command
  • Sites with many conventional detectors: warehouses, production facilities, educational buildings
  • Expanding a system based on the KS-02-250 controller

Frequently asked questions

How many detectors, and which types, can be connected?
Up to 32 conventional detectors on each of the four loops — smoke, heat and manual — provided the detector's standby current does not exceed 45 µA.
What can be connected to the module outputs?
To the four supervised outputs — sounders and light indicator panels: 24 V ± 20 %, load current up to 0.45 A per output. The dry-contact relay up to 250 V / 2 A is used to start fire suppression or smoke control, or to shut down ventilation.
How many addresses does the module occupy and how is it powered?
The module occupies 10 address slots on the panel. Power is DC 24 V ± 20 % from main and standby sources; current consumption excluding outputs is no more than 50 mA.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.