Addressable analogue fire control panel QR Systems PPK-02-250-0
Addressable analogue fire control panel QR Systems PPK-02-250-0 — фото 2
Addressable analogue fire control panel QR Systems PPK-02-250-0 — фото 3
Addressable analogue fire control panel QR Systems PPK-02-250-0 — фото 4
● QR Systems In stockNew

Addressable analogue fire control panel QR Systems PPK-02-250-0

Addressable analogue fire control panel for 250 addressable devices (loop and RF 868 MHz), CAN network up to 250 panels, RS-485, Wi-Fi, basic version, damper actuators: 0.

3 535 900 UZS
▸
Type
addressable analogue fire control panel, version 0
▸
Interfaces
CAN ×2, loop ×2, RS-485 ×2, RF 868 MHz (5 channels, XTEA 128-bit, up to 900 m), Wi-Fi 2400 MHz (up to 50 m)
▸
Addressable devices
250 on the loops and RF 868 MHz
▸
CAN network
up to 250 panels, up to 100 m without repeaters, 1 address in the network

Specifications

Type
addressable analogue fire control panel, version 0
Interfaces
CAN ×2, loop ×2, RS-485 ×2, RF 868 MHz (5 channels, XTEA 128-bit, up to 900 m), Wi-Fi 2400 MHz (up to 50 m)
Addressable devices
250 on the loops and RF 868 MHz
CAN network
up to 250 panels, up to 100 m without repeaters, 1 address in the network
Addressable loop
2 loops, up to 3000 m, up to 0.35 A per channel
Dampers
0 (basic version); the range also includes versions for 2, 4 and 7 dampers
Inputs
2 freely programmable, up to 20 V, line supervision 5 mA
Outputs
2 dry contact up to 220 V, 2 A; 2 supervised OUT1/OUT2, 24 V, 0.45 A
Power supply
DC 24 V ± 20 % main and backup; 0.22 A standby, 0.32 A Fire
Housing
IP20, 245×197×32 mm, max. 0.7 kg, −10 to +55 °C

Description

The QR Systems PPK-02-250-0 addressable analogue fire control panel is designed to monitor and control fire alarm, notification, fire suppression and smoke extraction systems as well as auxiliary building equipment involved in fire safety. The panel operates within a wired and wireless QR Systems addressable system: its own address space covers 250 devices on two addressable loops and the RF 868 MHz radio channel, and up to 250 panels are combined into a single distributed system over the redundant CAN interface. The PPK-02-250-0 version is the basic one: the number of connectable damper actuators is 0; it is chosen for sites where the panel handles alarm, notification and equipment control through its programmable inputs and outputs. Equipment is controlled through two freely programmable inputs, two dry-contact outputs and two supervised outputs; operating modes are shown on the built-in LCD with light and sound indication. The panel is intended for autonomous and centralised fire protection of buildings and is powered from main and backup DC 24 V sources.

Advantages

  • Address capacity of 250 devices on the loops (2 loops up to 3000 m, up to 0.35 A per channel) and the RF 868 MHz radio channel — wired and wireless devices on one panel
  • Redundant CAN interface (2 ports): up to 250 panels in a network, up to 100 m without repeaters — a distributed system at a large site
  • Basic version, damper actuators: 0 — for alarm and notification systems; smoke/fire dampers in the range are controlled by versions 2, 4 and 7
  • 2 programmable inputs, 2 dry-contact outputs (up to 220 V, 2 A) and 2 supervised outputs OUT1/OUT2 (24 V, 0.45 A) — flexible equipment control logic
  • RF 868 MHz radio channel (5 channels, XTEA 128-bit, up to 900 m), Wi-Fi 2400 MHz (up to 50 m) and 2 RS-485 interfaces — communication with devices and panel servicing
  • Built-in LCD and light and sound mode indication, average service life 10 years, MTBF 60 000 h — clear monitoring and long operation

Applications

  • Addressable fire alarm systems of buildings and structures with autonomous and centralised protection
  • Alarm and notification systems where equipment is controlled through the programmable inputs and outputs of the panel
  • Control of notification, fire suppression and building equipment through programmable outputs
  • Distributed systems of several panels combined over CAN at large sites
  • Sites with wired and wireless QR Systems addressable devices

Frequently asked questions

What does the last digit in the PPK-02-250 designation mean?
The last digit is the number of connectable smoke extraction and fire damper actuators: 0, 2, 4 or 7. This version is PPK-02-250-0, basic, damper actuators: 0. The other parameters are the same for all versions.
How many devices and panels can be combined?
One panel takes up to 250 addressable devices over the loop and RF 868 MHz interfaces; over the CAN interface up to 250 panels are combined into one network, and the panel occupies 1 address in the CAN network.
What are the power supply and consumption of the panel?
Main and backup power DC 24 V ± 20 %. Own current consumption is no more than 0.22 A in standby and no more than 0.32 A in Fire mode. Housing IP20, 245×197×32 mm, weight max. 0.7 kg, operating temperature −10 to +55 °C.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.