Fire and security control panel Rubezh-2OP prot.R3 with HASP Pro key (PPKOPU 011249-2-1)
Addressable Rubezh-2OP panel with R3 protocol: RS-485 network, 2 loops for up to 500 devices, HASP Pro key for FireSec Operational Task.
Specifications
- Loop protocol
- R3 (RUBEZH R3)
- Interfaces
- USB; RS-485; addressable loop
- Addressable loops
- 2 loops up to 3000 m, up to 250 devices per loop (up to 500 in total)
- Zones
- up to 500 fire zones
- Panel network
- up to 60 panels over RS-485
- Outputs
- relay 1: 30 V DC / 250 V AC, 3 A; relays 2–3: 125 V, 0,1 A; outputs 4–5: up to 300 mA
- Event log
- 10 240 events
- Power supply
- 10–14 V, 2 inputs; 0,4 A, up to 1,9 A with 500 devices
- Key
- HASP Pro for FireSec Operational Task
- Housing
- IP30, 200×160×50 mm, up to 1 kg, 0…+55 °C
Description
The Rubezh-2OP prot.R3 fire and security panel is an addressable control and indicating panel of the RUBEZH R3 line for fire and intrusion alarm, fire suppression, smoke exhaust and notification systems. The panel exchanges data with addressable devices via the R3 protocol over 2 addressable loops up to 3000 m long: each loop takes up to 250 devices, up to 500 per panel in total. On distributed sites up to 60 panels are networked over RS-485, and the panel connects to a computer via USB or through interface modules. The kit includes a HASP Pro hardware key for FireSec Operational Task software, which displays and controls the system from a computer; the licence scope is confirmed when ordering. Configuration is done in FireSec 3 Administrator, after which the panel controls the system autonomously.
Advantages
- R3 protocol on the loop — works with R3 series addressable detectors, interface modules and control modules
- 2 loops up to 3000 m with radial, ring or tree topology — flexible cable routing on site
- Up to 500 addressable devices and 500 fire zones — capacity reserve for large floors and buildings
- Network of up to 60 panels over RS-485 — distributed system with output to a central computer
- HASP Pro key included — FireSec Operational Task licence for monitoring the system from a computer
- Event log for 10 240 events and 2 power inputs — event history and power redundancy
Applications
- Administrative buildings and business centres with addressable fire alarm
- Facilities with automatic fire suppression and smoke exhaust
- Retail and public buildings with notification systems
- Industrial and warehouse complexes with several buildings on one RS-485 network
- Sites with a control room based on FireSec
Frequently asked questions
What is the HASP Pro key for?
How does this panel differ from Rubezh-2OP with HASP key?
How are several panels combined?
Product reviews
Questions & answers












