Manual fire call point Bolid IPR 513-3AM ver.01
Bolid IPR 513-3AM ver.01 manual fire call point for the S2000 addressable system with a built-in short-circuit isolator. Buy in Tashkent with delivery across Uzbekistan.
▸
Protection
Built-in short-circuit isolator
▸
Interfaces
S2000 controllers
▸
Application
Fire alarm
Specifications
- Protection
- Built-in short-circuit isolator
- Interfaces
- S2000 controllers
- Application
- Fire alarm
Bolid IPR 513-3AM ver.01 manual fire detector is a reliable element of an addressable fire alarm system, allowing personnel to instantly trigger an alarm by pressing a button. The device is designed for integration with S2000 series controllers and is equipped with a built-in short-circuit isolator, which ensures the stability of the entire loop in case of line damage. This is a solution from Bolid for facilities where high reliability and compatibility with already installed equipment are important.
Advantages
- Instant “Fire” signal triggering — one press switches the system to alarm mode without delay
- The built-in short-circuit isolator protects the addressable line from fault propagation in case of a short circuit
- Compatibility with S2000 controllers simplifies integration into existing Bolid systems
- The addressable design allows precise identification of the activation location on the facility plan
- The reliable button-type construction reduces the risk of accidental triggering
- Easy installation and maintenance reduce operating costs
Applications
- Administrative and office buildings — evacuation routes, corridors, stairwells
- Retail and warehouse complexes with Bolid addressable alarm systems
- Industrial enterprises where manual duplication of automatic detection is required
- Educational institutions, hospitals and facilities with mass presence of people
- Facilities with extensive addressable loops where short-circuit protection is critical
Frequently asked questions
Which devices is the IPR 513-3AM ver.01 compatible with?
The detector operates in addressable loops of S2000 series controllers manufactured by Bolid and is compatible with the control and indicating equipment of this line.
Why is the built-in short-circuit isolator needed?
The isolator automatically disconnects the damaged section of the loop in case of a short circuit, maintaining the operability of the remaining detectors on the line.
How do I reset the detector after triggering?
Resetting is performed from the system control panel or directly on the device in accordance with the operating instructions.
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Product reviews
Questions & answers
Similar: Detectors
Whole category →New

Bolid S2000-IPG Gas Fire Detector (CO)
from 865 900 UZS
New

Bolid DIP-34A-04 Addressable Analogue Smoke Detector
from 432 900 UZS
New

Bolid DIP-34A-05 Addressable Analogue Smoke Detector
from 469 900 UZS
New

Bolid IPR 513-3AM Addressable Manual Call Point
from 221 900 UZS

Glass break detector Bolid S2000-ST ver.04
from 370 900 UZS

Addressable magnetic contact detector Bolid S2000-SMK ver.05
from 147 900 UZS