Wired addressable expander QR Systems AR-1
Wired addressable expander QR Systems AR-1 — фото 2
● QR Systems In stockNew

Wired addressable expander QR Systems AR-1

Addressable expander connecting up to 3 conventional detectors or dry-contact devices to the PLS line: 1 address slot, loop-powered, 0.17 mA.

184 900 UZS
▸
Interface
PLS
▸
Address slots
1
▸
Detectors per loop
up to 3
▸
Line to dry contact
up to 10 m

Specifications

Interface
PLS
Address slots
1
Detectors per loop
up to 3
Line to dry contact
up to 10 m
Power supply
from the PLS line
Current consumption
0.17 mA in standby, 0.18 mA with loop short
Indication
LED
Operating temperature
−25…+55 °C
Housing
IP20, 40×56×20 mm, max 30 g
Average service life
10 years

Description

The QR Systems AR-1 wired addressable expander connects conventional fire detectors, buttons and other devices with a dry-contact output to a QR Systems addressable analogue fire alarm system and transmits alarms to the control panel. Up to three detectors connect to the expander loop, and the line to the dry-contact device can be up to 10 m long. The expander is an addressable device that occupies one slot on the panel and is powered from the PLS line: 0.17 mA in standby and 0.18 mA with a loop short circuit. An LED indicator shows the device state and operating mode. It is used with the control panel and the KS-02-250 system controller, and its 40×56×20 mm size and 30 g weight let it fit in a standard junction box.

Advantages

  • Up to 3 conventional detectors in one addressable point — ordinary detectors work in an addressable system
  • Dry-contact inputs — connection of buttons, actuating and technical systems with alarms sent to the panel
  • Powered from the PLS line, 0.17 mA — no external supply needed
  • One address slot — economical use of address space
  • 40×56×20 mm and 30 g — fits in a standard junction box
  • Operating temperature from −25 to +55 °C — installation in various climatic conditions

Applications

  • Migrating conventional fire detectors to a QR Systems addressable analogue system
  • Connecting buttons and devices with a dry-contact output
  • Monitoring building and technical systems through the fire alarm system
  • Small rooms and zones with 1–3 detectors
  • Step-by-step fire alarm upgrades keeping the installed detectors

Frequently asked questions

How many detectors can be connected to AR-1?
Up to three conventional detectors in one loop; all of them appear as one addressable point and occupy one slot on the panel.
Does the expander need an external power supply?
The expander is powered from the PLS line and draws no more than 0.17 mA in standby and 0.18 mA with a loop short circuit.
What is the maximum line length to the device?
Between the expander and the dry-contact device — no more than 10 m. The expander works with the control panel and the KS-02-250 system controller.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.