Addressable fire interface module Rubezh AMP-4
Addressable module for 4 loops of conventional detectors with 4 open-collector outputs, for Rubezh panels on the R1 protocol.
Specifications
- Product line
- RUBEZH R1
- Loops
- 4, each with its own address
- Detectors
- conventional smoke, heat, manual and intrusion
- Outputs
- 4 open-collector, activated by “Fire” in their own loop
- Notification
- OPOP 1-8 indicator panels, OPOP 2-35 sounders
- Loop supervision
- open and short circuit
- Power supply
- external 12 V, addressable loop galvanically isolated
- Compatibility
- Rubezh-2AM, Rubezh-4A, Rubezh-2OP, Vodoley PPKPU
- Mounting
- DIN rail (bracket ordered separately)
Description
The Rubezh AMP-4 addressable fire interface module connects conventional fire and intrusion detectors to an addressable system of the RUBEZH R1 line. The module supervises four loops, and each loop is recognised in the system as a separate device with its own address. Four open-collector outputs switch on by the “Fire” signal of their loop and control OPOP 1-8 light indicator panels, OPOP 2-35 sounders and other external devices. The module works with Rubezh-2AM, Rubezh-4A, Rubezh-2OP panels and Vodoley series PPKPU; its configuration is set from the control panel. Power comes from an external 12 V supply, and the addressable loop is galvanically isolated from the power supply.
Advantages
- Four loops in one housing — each loop has its own address, so the activation point is shown down to the loop
- Conventional smoke, heat, manual and intrusion detectors — existing detectors stay in service when moving to an addressable system
- 4 open-collector outputs — local activation of indicator panels and sounders on fire in the loop
- Loop supervision for open and short circuit — a line fault is shown on the panel immediately
- Galvanic isolation of the addressable loop from the power supply — the loop is separated from the module’s power circuits
- DIN rail mounting (bracket ordered separately) — neat installation in a cabinet
Applications
- Migrating conventional loops to a Rubezh R1 addressable system
- Expanding existing systems on Rubezh-2AM, Rubezh-4A, Rubezh-2OP and Vodoley panels
- Rooms with local light indicator panels and sounders
- Industrial and warehouse premises with intrusion and fire loops
- Administrative buildings during step-by-step fire alarm upgrades