Class A1R addressable analogue heat detector: triggers at a fixed temperature of +54…+65 °C and on the rate of temperature rise, loop-powered, 1 address slot.

169 900 UZS
▸
Type
addressable analogue fixed-temperature and rate-of-rise heat detector
▸
Class
A1R
▸
Interface
PLS
⚡
Power supply
from the PLS loop

Specifications

Type
addressable analogue fixed-temperature and rate-of-rise heat detector
Class
A1R
Interface
PLS
Power supply
from the PLS loop
Current consumption
no more than 0.24 mA (standby), 0.26 mA (Fire)
Address slots
1
Response temperature
+54…+65 °C
Operating temperature
−25…+55 °C
Protection rating
IP20
Dimensions
Ø 92 × 42 mm
Weight
79 g
Colour
white

Description

The QR Systems IP 101-102-A1R (white housing) addressable analogue fixed-temperature and rate-of-rise heat fire detector detects fires accompanied by a temperature increase in the monitored space and sends a Fire signal, as well as signals about its own technical condition, to QR Systems panels or controllers. The detector identifies a fire in two ways: when the maximum temperature in the +54 to +65 °C range is reached, and by the rate of temperature rise. Communication and power are over the wired PLS loop; the detector occupies one address slot and is detected automatically by the panel. The device measures the PLS voltage at its installation point and can be switched to service mode without losing its binding. Suitable for rooms where smoke detectors are impractical.

Advantages

  • Two detection methods: maximum temperature and rate of rise — responds to both slow and rapid temperature increases
  • Response temperature +54 to +65 °C — class A1R
  • Generates Fire and Fault signals — the panel sees both the alarm and the detector's condition
  • Automatic detection in the system — fast commissioning
  • PLS voltage measurement at the installation point — loop diagnostics without additional instruments
  • Current consumption no more than 0.24 mA in standby and 0.26 mA in Fire mode — low load on the loop

Applications

  • Kitchens, boiler rooms and technical rooms where smoke and steam interfere with smoke detectors
  • Garages and enclosed parking
  • Production shops and workshops
  • Storage rooms with dust or aerosols in the air
  • Sites with a QR Systems addressable analogue fire alarm system

Frequently asked questions

What does fixed-temperature and rate-of-rise mean?
The detector uses two methods to identify a fire: reaching the maximum temperature (+54 to +65 °C) and the rate of temperature rise. This lets it respond both to gradual heating and to a sudden temperature jump.
How is the detector connected to the system?
Over the wired PLS loop, which also powers it. The detector occupies one address slot, is detected automatically in the system and sends Fire and Fault signals to the QR Systems panel or controller.
Can the detector be serviced without reconfiguring the system?
Yes, the detector switches to service mode without losing its binding, and the built-in PLS voltage measurement helps check the loop at the installation point.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.