QR Systems IP 101-102-A1R/Wh addressable analogue rate-of-rise heat fire detector
Class A1R addressable analogue heat detector: triggers at a fixed temperature of +54…+65 °C and on the rate of temperature rise, loop-powered, 1 address slot.
Specifications
- Type
- addressable analogue fixed-temperature and rate-of-rise heat detector
- Class
- A1R
- Interface
- PLS
- Power supply
- from the PLS loop
- Current consumption
- no more than 0.24 mA (standby), 0.26 mA (Fire)
- Address slots
- 1
- Response temperature
- +54…+65 °C
- Operating temperature
- −25…+55 °C
- Protection rating
- IP20
- Dimensions
- Ø 92 × 42 mm
- Weight
- 79 g
- Colour
- white
Description
The QR Systems IP 101-102-A1R (white housing) addressable analogue fixed-temperature and rate-of-rise heat fire detector detects fires accompanied by a temperature increase in the monitored space and sends a Fire signal, as well as signals about its own technical condition, to QR Systems panels or controllers. The detector identifies a fire in two ways: when the maximum temperature in the +54 to +65 °C range is reached, and by the rate of temperature rise. Communication and power are over the wired PLS loop; the detector occupies one address slot and is detected automatically by the panel. The device measures the PLS voltage at its installation point and can be switched to service mode without losing its binding. Suitable for rooms where smoke detectors are impractical.
Advantages
- Two detection methods: maximum temperature and rate of rise — responds to both slow and rapid temperature increases
- Response temperature +54 to +65 °C — class A1R
- Generates Fire and Fault signals — the panel sees both the alarm and the detector's condition
- Automatic detection in the system — fast commissioning
- PLS voltage measurement at the installation point — loop diagnostics without additional instruments
- Current consumption no more than 0.24 mA in standby and 0.26 mA in Fire mode — low load on the loop
Applications
- Kitchens, boiler rooms and technical rooms where smoke and steam interfere with smoke detectors
- Garages and enclosed parking
- Production shops and workshops
- Storage rooms with dust or aerosols in the air
- Sites with a QR Systems addressable analogue fire alarm system
Frequently asked questions
What does fixed-temperature and rate-of-rise mean?
How is the detector connected to the system?
Can the detector be serviced without reconfiguring the system?
Related articles
- Wireless Addressable Fire Alarms: How the Rubezh R3 and Bolid S2000R Radio Links Work and When They Beat Cable
- SAT Solutions price index, September 2026: what makes up the budget for video surveillance, access control and fire alarms
- Uzbekistan's regulations on video surveillance, access control and fire alarms: a reference with document numbers
Product reviews
Questions & answers