Addressable analogue fire control and indicating panel QR Systems PPK-02-500-0
Addressable analogue fire control and indicating panel QR Systems PPK-02-500-0 — фото 2
Addressable analogue fire control and indicating panel QR Systems PPK-02-500-0 — фото 3
Addressable analogue fire control and indicating panel QR Systems PPK-02-500-0 — фото 4
● QR Systems In stockNew

Addressable analogue fire control and indicating panel QR Systems PPK-02-500-0

Addressable analogue fire panel for 500 addressable devices (loop and 868 MHz radio), up to 250 panels in a CAN network, version without damper drives, RS-485, Wi-Fi.

4 412 900 UZS
▸
Type
addressable analogue fire panel, wired and radio
▸
Addressable devices
500 (loop and RF 868 MHz)
▸
Interfaces
CAN ×2 (up to 250 panels, up to 100 m, 1 address), RS-485 ×2 (up to 100 m), Wi-Fi 2400 MHz (up to 50 m)
▸
Addressable loop
2 lines, up to 3000 m, up to 0.35 A per channel

Specifications

Type
addressable analogue fire panel, wired and radio
Addressable devices
500 (loop and RF 868 MHz)
Interfaces
CAN ×2 (up to 250 panels, up to 100 m, 1 address), RS-485 ×2 (up to 100 m), Wi-Fi 2400 MHz (up to 50 m)
Addressable loop
2 lines, up to 3000 m, up to 0.35 A per channel
Radio channel
868 MHz, 5 channels, XTEA 128 bit, up to 25 mW, up to 900 m
Smoke/fire dampers
0 (version without damper drives)
Inputs/outputs
2 programmable inputs (line supervision 5 mA); 2 dry contact (220 V, 2 A); 2 supervised (24 V, 0.45 A)
Power supply
DC 24 V ± 20 % (main and backup); 0.22 / 0.32 A
Housing
IP20, 245×197×32 mm, up to 0.7 kg, −10…+55 °C
Average service life
10 years, MTBF 60 000 h

Description

The QR Systems PPK-02-500-0 addressable analogue fire control and indicating panel is the central unit of an addressable fire alarm system: it monitors detectors and addressable modules and controls notification, fire suppression, smoke extraction and the building equipment involved in fire safety. This is the 500-device version: the number 500 in the designation stands for the enlarged address space, while the other parameters are the same as for the PPK-02-250. Addressable devices connect over two addressable loops of up to 3000 m each or over the RF 868 MHz radio channel with XTEA 128-bit encryption and a range of up to 900 m in open terrain. Up to 250 panels combine into a single distributed system over a redundant CAN interface, while the built-in LCD display and light and sound indication show the operating modes. The 0 in the designation means a version without drives for smoke extraction and fire dampers: the panel controls equipment through two freely programmable inputs, two dry-contact outputs and two supervised outputs. The panel is designed for continuous round-the-clock indoor operation and suits design organisations, installation companies and building maintenance services in Tashkent and across Uzbekistan.

Advantages

  • 500 addressable devices over the loop and the RF 868 MHz radio channel — wired and wireless detectors and modules in one system
  • Up to 250 panels in a CAN network (up to 100 m without repeaters, 1 address per panel) — a distributed system for a large site
  • 868 MHz radio channel: 5 channels, XTEA 128-bit encryption, power up to 25 mW, up to 900 m — wireless devices where cabling is hard to run
  • Version without damper drives — a base panel for detection and notification; versions -2, -4 and -7 of the same series add damper control
  • 2 programmable inputs, 2 dry-contact outputs (220 V, 2 A) and 2 supervised outputs (24 V, 0.45 A) — flexible connection of notification and building equipment
  • LCD display, light and sound indication, two RS-485 ports and 2400 MHz Wi-Fi — operating modes visible on site, plus additional communication channels

Applications

  • Administrative and office buildings with addressable fire detection
  • Shopping centres, warehouses and production buildings with notification, smoke extraction and fire suppression systems
  • Distributed sites of several buildings linked over a CAN network
  • Sites where some detectors and modules connect over the RF 868 MHz radio channel
  • Residential complexes, hotels, educational and medical institutions

Frequently asked questions

How many addressable devices and panels does the PPK-02-500-0 support?
Its own address space is 500 addressable devices over the addressable loop and the RF 868 MHz radio channel. Over the CAN interface up to 250 panels combine into one system, each occupying one address in the CAN network; the CAN line is up to 100 m long without repeaters. The number 500 in the designation is the version for 500 addressable devices; the other parameters match the PPK-02-250.
What does the last digit in the PPK-02-500-0 designation mean?
The number of smoke extraction and fire damper drives the panel controls directly: versions 0, 2, 4 and 7 are produced. For the PPK-02-500-0 the 0 means a version without damper drives; versions -2, -4 and -7 control 2, 4 and 7 dampers respectively (AC 220/230 V, 50/60 Hz, up to 2 A).
How is the panel powered and in what conditions does it operate?
Main and backup power is DC 24 V ± 20 %; the panel's own current consumption is no more than 0.22 A in standby and 0.32 A in Fire mode. The panel is installed indoors: operating temperature from −10 to +55 °C, humidity up to 93 % at +40 °C, IP20 housing, dimensions 245×197×32 mm, weight up to 0.7 kg. Average service life is 10 years, mean time between failures 60 000 h.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →