QR Systems UDP-513-102A addressable remote release unit (emergency exit)
Addressable remote release unit for unlocking emergency exits: built-in short-circuit isolator, tamper switch, loop-powered, 1 address slot, actuation force no less than 25 N.
Specifications
- Type
- addressable remote release unit, emergency exit
- Interface
- PLS
- Power supply
- from the PLS loop
- Current consumption
- no more than 0.16 mA (standby), 0.2 mA (Release)
- Address slots
- 1
- Short-circuit isolator
- built-in, activation 10 V, restore 3 V, current up to 1 A
- Tamper switch
- yes
- Actuation force
- no less than 25 N
- Operating temperature
- −25…+55 °C, humidity up to 93 % at +40 °C
- Protection rating
- IP20
- Dimensions
- 85 × 85 × 40 mm
- Weight
- no more than 95 g
- Average service life
- 10 years, 60 000 h MTBF
Description
The QR Systems UDP-513-102A addressable remote release unit is intended for sending emergency signals to unlock evacuation and emergency exits in a QR Systems addressable fire alarm system and for directly unlocking the exits. It is used with the addressable analogue fire control and indicating panel and the KS-02-250 system controller; communication and power are over the wired PLS loop, and the unit occupies one address slot in the system. The built-in short-circuit isolator activates at 10 V and restores at 3 V, cutting off the damaged section of the loop. The housing is protected against accidental activation, has a tamper switch and LED status indication; the unit monitors its own operability and measures the PLS voltage at its installation point. An extractor key for resetting is supplied.
Advantages
- Manual unlocking of an emergency exit — evacuation starts on a person's command, without waiting for automation
- Built-in short-circuit isolator — damage to one section of the loop does not stop the other devices
- Protection against accidental activation and actuation force no less than 25 N — no release from an accidental touch
- Tamper switch and operability monitoring — the panel sees the unit's condition
- PLS voltage measurement at the installation point — loop diagnostics without additional instruments
- Current no more than 0.16 mA in standby and 0.2 mA on release, 10-year service life — economical, long operation
Applications
- Evacuation and emergency exits of office and administrative buildings
- Shopping centres, hotels and public buildings
- Educational and medical facilities
- Production and warehouse sites
- Sites with a QR Systems addressable fire alarm system based on the panel and the KS-02-250 controller