QR Systems MK-1 switching module
QR Systems MK-1 switching module — фото 2
● QR Systems In stockNew

QR Systems MK-1 switching module

Line supervision module for sounders and beacons on the outputs of the control panel and KS controller: up to 1 A, 30 V DC, 0 addresses, 20×10×4 mm, mounts inside the sounder.

17 890 UZS
▸
Type
switching module, sounder line supervision
▸
Application
with the QR Systems control panel and KS-02-250 controller
▸
Operating voltage
30 V DC maximum
▸
Load current
up to 1 A

Specifications

Type
switching module, sounder line supervision
Application
with the QR Systems control panel and KS-02-250 controller
Operating voltage
30 V DC maximum
Load current
up to 1 A
Address slots
0
Wire cross-section
0.35 mm²
Operating temperature
−25…+55 °C
Protection rating
IP30
Dimensions
20×10×4 mm (without wires)
Weight
up to 3 g

Description

The QR Systems MK-1 switching module supervises the line to audible and visual fire alarm devices connected to the outputs of the addressable control panel and the KS-02-250 system controller. The module is designed for notification circuits: it is placed in the sounder circuit and lets the panel supervise the line all the way to the device. The 20×10×4 mm body, excluding wires, fits inside the sounder housing or in a junction box. The module takes no address slots, so the panel capacity stays available for detectors. Connection is by wire leads of 0.35 mm² cross-section according to the passport diagram: panel output and a 24 V alarm device.

Advantages

  • Supervision of the sounder line — the panel sees the state of the circuit to the audible and visual devices
  • Load current up to 1 A at 30 V DC — works with alarm devices of different power
  • 20×10×4 mm and up to 3 g — fits inside the sounder housing or a junction box
  • 0 address slots — the panel's address capacity stays available for detectors
  • Temperature range −25…+55 °C — operation in unheated rooms
  • Protection rating IP30 — for installation inside a sounder or a box

Applications

  • Sounder and beacon circuits of notification systems in QR Systems installations
  • Supervising the line to exit signs and sirens on panel outputs
  • Connecting alarm devices to the KS-02-250 controller
  • Sites with unheated areas: warehouses, car parks, technical rooms

Frequently asked questions

Why is the MK-1 needed if the sounder is already connected to the panel output?
The module provides supervision of the line from the alarm device: the control panel receives information about the state of the circuit to the audible or visual device connected to its output.
Does the module occupy an address in the system?
No, the number of address slots occupied is 0. The panel's address capacity remains fully available for detectors and addressable devices.
What line parameters are allowed?
Maximum operating voltage 30 V DC, maximum load current 1 A. Connection wires are 0.35 mm² in cross-section; according to the passport diagram the alarm device is connected to the 24 V fire alarm circuit.
🛠Turnkey serviceFire Alarm and Fire Suppression Installation in Uzbekistan — design and installation→
💬
Need help choosing?
Our engineer will pick the right equipment for your needs and send a quote within one business day.
Get a consultation →

Product reviews

Rate our work
Tap the stars

Questions & answers

Ask the engineer

Compatibility, installation, selection — we'll answer and publish the reply on this page.